Sigma FSP Multi-Turn Rollover Handling Technical Note

AI-enhanced description

This technical note describes how to configure a Sigma FSP amplifier with an absolute encoder to manage position loss caused by multi-turn limit rollover. It provides step-by-step setup instructions, including setting the Rotation_Base parameter and multi-turn limit, and explains how to use the Rotation_Demand_Position variable to maintain correct positioning in applications involving rotational systems.