SLIO Counter and Frequency Measurement Modules in MotionWorks IEC Application Note
This application note details how to use Yaskawa SLIO counter and frequency measurement modules with MotionWorks IEC software, including the specific control word bits (Software Gate and CTRL_FM_START) required to enable counting or frequency measurement. It provides a reference table of supported modules (050-1BA00, 050-1BA10, 050-1BB00, 050-1BB30, 050-1BB40, 050-1BS00) with their control word address offsets and enable/disable bit positions.